Hunting porosity: a snowman under X-rays

Technical articles

To show what X-ray tomography can reveal, we chose an object everyone recognises: a small plastic snowman figurine. It is only about 3 cm tall, yet it combines everything that makes industrial inspection difficult: several assembled parts, hollow areas and an interior that is completely invisible to the naked eye.

Our aim: to show how this non-destructive testing (NDT) technique can detect, measure and locate porosity (the small air bubbles trapped in the material) without ever damaging the part.

Step 1: 3D mapping and detection of porosity

3D X-ray tomography reconstruction of a snowman with its internal porosity colour-coded by volume
Detail of the 3D reconstruction of the snowman showing internal porosity, the largest in red

3D tomography reconstruction: the material is rendered transparent to reveal internal voids. Each pore is colour-coded by volume, from blue (smallest) to red (largest).

By scanning the snowman with X-rays, we build its 3D digital twin. The software makes the plastic transparent and isolates only the internal voids: the pores. To make the analysis readable at a glance, each pore is colour-coded according to its volume (scale from 0 to 0.061 mm³). It is immediately clear that the object contains a great many pores, most of them tiny (in blue) and spread throughout the volume, and that a few stand out clearly by their size.

Step 2: From visual detection to measurement

Seeing a defect is interesting; measuring it is essential to judge whether a part is compliant. We identified the five largest pores and recorded the exact volume of each.

  • 0.060 mm³ largest pore (indication 1)
  • 0.040 mm³ second largest pore (indication 2)
  • 0.025 to 0.031 mm³ indications 3, 4 and 5
3D view of the snowman with the five largest pores identified and their volume in mm³
The five largest pores, identified and measured by volume: from 0.060 mm³ (indication 1, in red) to 0.025 mm³ (indication 5).
Another 3D view of the snowman on a grey background with pore indications numbered 1 to 5
Same analysis on a grey background: the indications are spread across the head and the body, with indication 1 at the bottom of the body.

Step 3: Locating each defect with virtual cross-sections

A pore does not have the same impact depending on where it is. Virtual cross-sections make it possible to locate it precisely within the object along three planes (top, right and front views), alongside the 3D view.

Virtual cross-sections of the snowman along three planes and 3D view locating the largest pore
Virtual cross-sections along three planes and 3D view: indication 1 (0.060 mm³, in red) is located in each view.
Close-up of the 0.060 mm³ pore in the snowman virtual cross-sections
Close-up of indication 1: the pore lies very close to the outer surface of the body (scale bars from 2.5 to 5 mm).
The same virtual cross-sections of the snowman without annotations, with pores colour-coded within the material
The same cross-sections without annotations: pores appear colour-coded directly within the material.

In an industrial context, it is the combination of a pore’s size and its position, in particular its proximity to the surface, that makes it possible to judge how critical it is.

Step 4: Reading the assembly from the inside

Tomography does not only show porosity: it also reveals how the object is built. In these cross-sections, you can see several nested parts, hollow areas and thin gaps between components (the air appears dark).

Front virtual cross-section of the snowman showing the hat, head and body with their internal cavities
Front cross-section: hat, head and body with their internal cavities.
Right virtual cross-section of the snowman showing circular elements inserted in the head and body
Right cross-section: circular elements inserted in the head and body, surrounded by a thin gap.

This information is valuable for inspecting an assembly: we check that each part is present, its position, the gaps and any debonding, without dismantling anything.

X-ray tomography: seeing and measuring what the eye cannot

The pores observed here have no consequence for a figurine. They would, however, be decisive in a sealed fitting, a medical implant, an electronic housing or a safety-critical part. This example shows the value of X-ray tomography: visualising the inside of the material, quantifying defects (3D metrology), understanding their origin and adjusting the manufacturing process, all without destroying the sample.