Privileged access to the ESRF Synchrotron beamlines — when standard industrial imaging reaches its limits.
The problem: defects invisible to conventional industrial tomography
Some defects are not easy to see. Metal whiskers a few microns long, micro-bubbles in a low-density material, incipient cracks in a translucent component: beyond a certain fineness, a standard industrial tomograph can no longer tell the defect from the background noise. This is where phase contrast comes in, an imaging technique that fundamentally changes what can be observed inside a part.
INSIDIX has privileged access to the beamlines of the ESRF Synchrotron (European Synchrotron Radiation Facility) in Grenoble. This access makes it possible to handle cases where laboratory analysis reaches its limits of resolution or contrast.
The method: how a synchrotron tomography beamline works
The ESRF Synchrotron generates ultra-bright X-rays by accelerating electrons. The beam, focused and directed towards different beamlines, offers an image quality that conventional X-ray sources cannot achieve.
A synchrotron tomography beamline is made up of four elements: an X-ray source (wiggler or bending magnet), optics to condition the beam (filters, slits, lenses), a sample mounted on a rotation stage, and a high-resolution detector with a scintillator.

INSIDIX works with several beamlines depending on the need:
- BM5 — High resolution : down to 0.3 µm, energies 25-150 keV, parts up to 30 kg / Ø 30 cm / 50 cm, propagation distance up to 3.5 m for phase contrast, automatic sample-changing robot.
- BM18 : 220 m beamline, resolution down to 1 µm, capacity 30 kg / Ø 30 cm / 50 cm, propagation distance up to 36 m, energies 50-280 keV with a 30 cm wide beam.
- BM18 — Large-sample stage : the largest synchrotron sample stage in the world, capacity 300 kg / Ø 180 cm / 240 cm high.
- ID19 — Ultra-fast imaging : 145 m beamline, energies 15-250 keV, fast tomography and ultra-fast radiography up to 100,000 frames per second.
Phase contrast in practice: an example on a rock
Phase contrast makes it possible to visualise low-density materials that are invisible in standard industrial tomography. Drag the slider to compare the two views of the same rock sample, obtained with ESRF facilities.
A concrete case: an Intel chip analysed at the ESRF
To show what access to the synchrotron changes in practice, INSIDIX analysed a demonstration electronic component: an Intel chip in a BGA package. The question asked: is the inside of the package sound, in particular around the chip and its bonding wires, where a delamination or detachment would be invisible from the outside?



First step, in the laboratory. 2D radiography gives the overall view of the package without destroying it, and acoustic microscopy, which is sensitive to interfaces, already highlights delaminations. The inspection is then taken further: to precisely locate the defect within the thickness of the package and understand its nature, it has to be seen in cross-section, and this is where the very high-resolution tomography of the ESRF takes over. The tomography scans were carried out at a resolution of 0.7 µm.
Zoom on the chip: a delamination in the silver adhesive

In this overall view, we can distinguish the chip (smooth area), the bonding wires (bright dots) and the silver-filled adhesive layer under the chip (light, grainy area). A dark gap, with no material, runs through this layer: this is the delamination, which tomography makes it possible to locate precisely in cross-section.

The zoom shows that the silver adhesive is split in two by this gap, with a crack and a detachment that break the contact between the chip and its substrate.
This level of detail, obtained without opening or destroying the component, makes it possible to locate the interface concerned, measure the extent of the defect and investigate its origin (bonding, process, thermal stress) before deciding on corrective action.
Points to watch
The power of the synchrotron comes with specific constraints that must be anticipated at the start of a project:
- Browning : translucent materials (glass, lenses, plastic) can turn brown under the effect of the high-energy beam — a point of vigilance to build in from the definition of the protocol.
- Damage to electronics : some sensitive components can be damaged by exposure. INSIDIX assesses this risk upstream for each sample.
Another structural difference compared with laboratory analysis: the sequence of steps is partly reversed.
Step
Centring
Scan
Reconstruction and analysis
Lab
Quick and easy
Slow
Identical
Synchrotron
Slow and more complex
Fast (a few minutes)
Identical
The deliverable
At the end of a synchrotron session, INSIDIX provides a complete analysis report: reconstructed images and 3D volumes, annotated dimensional measurements, quantification of the defects detected, and technical recommendations that your quality or R&D teams can use directly.