CT metrology of a plastic part: 3D reconstruction and thickness

Case studies

The challenge in CT metrology of a plastic part

For this CT metrology case on a plastic part, a manufacturer in the plastics industry had to validate the dimensional conformity of an injection-moulded part before series production. Specifically, the specification required inspection of internal and external dimensions (inaccessible by probing), verification of wall-thickness uniformity, and overall geometric conformity against the CAD model — all without damaging the part.

On this example of an injection-moulded cap, we illustrate the full range of analyses that can be carried out.

Step 1 — 3D reconstruction by CT tomography

The Nikon XT H 225 ST tomograph scans the part at high resolution. From this data, the 3D reconstruction generates a complete digital model that reveals all internal geometries, including those invisible from the outside.

3D reconstruction by CT tomography of the injection-moulded plastic cap — full view of the scanned volume
Material segmentation histogram — differentiation of volumes and internal interfaces

3D reconstruction by tomography makes it possible to view the part in its entirety, including internal geometries invisible from the outside. Here we can distinguish the ribs, vents and details of the cap’s internal cavity. In addition, the segmentation histogram (right) differentiates the materials and isolates the volumes of interest.

Step 2 — Dimensional measurement

VGStudio Max measures key dimensions directly on the 3D model. The operator then compares diameters, heights, bore positions and flange thicknesses with the nominal values on the drawing.

Dimensional measurement by CT metrology — measurements on virtual sections of the plastic cap
Complete dimensional analysis in VGStudio Max — multi-panel view of the plastic cap

The operator carries out the dimensional measurements directly on the virtual sections extracted from the CT volume. In other words, diameters, angles and thicknesses are measured without contact and without cutting the part.

Step 3 — Wall thickness

Colour mapping analyses wall thickness across the whole 3D volume. Concretely, each area of the part is given a colour proportional to its local thickness, which makes it possible to immediately identify out-of-tolerance areas or thinning linked to the injection process.

Wall-thickness colour map — CT metrology of an injection-moulded plastic cap
Complete 3D wall-thickness analysis — multi-angle views of the moulded part

The wall-thickness map colours each point on the surface according to its thickness. More precisely, blue indicates the thinnest areas and green the nominal areas. The histogram at the top right shows the statistical distribution — here an average thickness of 0.54 mm.

Step 4 — CAD comparison

The software overlays the 3D model from the CT scan onto the original CAD file (STEP/STL). This geometric comparison highlights the dimensional deviations between the real part and its nominal definition, using a colour map of deviations.

CAD comparison — overlay of the CT scan and the nominal model with a map of dimensional deviations
3D CAD comparison — map of geometric deviations of the moulded part

The software overlays the scanned part onto the original CAD model. Green indicates conforming areas, while red and blue indicate positive and negative deviations. In addition, the coloured arrows on the section quantify the direction and magnitude of each deviation.

Results of CT metrology on a plastic part

In the end, this CT metrology study on a plastic part shows that in a single acquisition, INSIDIX delivers a complete analysis: 3D reconstruction, dimensional measurement, wall-thickness mapping and CAD comparison. Thanks to this approach, the customer validates the conformity of their moulded part before series launch, without cutting or destroying the sample. In summary, the lead time is 5 working days.

Do you need to validate a plastic part before production? Contact us — results in 5 working days.