The challenge in CT metrology of a plastic part
For this CT metrology case on a plastic part, a manufacturer in the plastics industry had to validate the dimensional conformity of an injection-moulded part before series production. Specifically, the specification required inspection of internal and external dimensions (inaccessible by probing), verification of wall-thickness uniformity, and overall geometric conformity against the CAD model — all without damaging the part.
On this example of an injection-moulded cap, we illustrate the full range of analyses that can be carried out.
Step 1 — 3D reconstruction by CT tomography
The Nikon XT H 225 ST tomograph scans the part at high resolution. From this data, the 3D reconstruction generates a complete digital model that reveals all internal geometries, including those invisible from the outside.


3D reconstruction by tomography makes it possible to view the part in its entirety, including internal geometries invisible from the outside. Here we can distinguish the ribs, vents and details of the cap’s internal cavity. In addition, the segmentation histogram (right) differentiates the materials and isolates the volumes of interest.
Step 2 — Dimensional measurement
VGStudio Max measures key dimensions directly on the 3D model. The operator then compares diameters, heights, bore positions and flange thicknesses with the nominal values on the drawing.


The operator carries out the dimensional measurements directly on the virtual sections extracted from the CT volume. In other words, diameters, angles and thicknesses are measured without contact and without cutting the part.
Step 3 — Wall thickness
Colour mapping analyses wall thickness across the whole 3D volume. Concretely, each area of the part is given a colour proportional to its local thickness, which makes it possible to immediately identify out-of-tolerance areas or thinning linked to the injection process.


The wall-thickness map colours each point on the surface according to its thickness. More precisely, blue indicates the thinnest areas and green the nominal areas. The histogram at the top right shows the statistical distribution — here an average thickness of 0.54 mm.
Step 4 — CAD comparison
The software overlays the 3D model from the CT scan onto the original CAD file (STEP/STL). This geometric comparison highlights the dimensional deviations between the real part and its nominal definition, using a colour map of deviations.


The software overlays the scanned part onto the original CAD model. Green indicates conforming areas, while red and blue indicate positive and negative deviations. In addition, the coloured arrows on the section quantify the direction and magnitude of each deviation.
Results of CT metrology on a plastic part
In the end, this CT metrology study on a plastic part shows that in a single acquisition, INSIDIX delivers a complete analysis: 3D reconstruction, dimensional measurement, wall-thickness mapping and CAD comparison. Thanks to this approach, the customer validates the conformity of their moulded part before series launch, without cutting or destroying the sample. In summary, the lead time is 5 working days.
Do you need to validate a plastic part before production? Contact us — results in 5 working days.